Home/Editorial Standards
How we writeEditorial Standards
How we name our services, the limits we always state, and the rules our writing follows.
Service names
| In plain words | Our service name |
|---|---|
| Purity, identity and amount | Peptide Purity & Characterization |
| Mass and structure | Mass Spectrometry & Structural Analysis |
| Binding | Binding Affinity & Kinetics |
| Effect on a receptor | Receptor Pharmacology & Selectivity |
| Effects on unintended targets | Off-Target Profiling |
| Gene testing | Gene Expression & Transcriptomics |
| Protein measurements | Proteomics & Biomarker Analysis |
| Effect on cells | Biological Activity & Functional Assays |
| Shelf-life testing | Stability & Degradation |
| Building a test method | Analytical Method Development |
| Test certificates | Reports & Verification |
Limits we always state
- Purity (HPLC %) is not the same as the amount of peptide in the vial.
- A matching molecular mass does not prove the full sequence.
- A library match or a matching retention time is a tentative identification; a confirmed identity needs a reference standard and a second, independent method.
- Strong binding is not the same as a strong effect.
- Reaching a receptor does not prove that the receptor is switched on.
- An off-target check covers the targets tested, not every possible interaction.
- A change in gene activity does not by itself prove how a treatment works.
- A change in a gene's RNA does not show that the protein, or its activity, changed.
- A targeted protein panel measures the proteins chosen for it; it is not a survey of every protein.
- A change in a biomarker does not by itself prove that a treatment works.
- Not detected means below the test's detection limit, not proof that something is absent.
- Stability results apply only to the conditions, methods and time periods tested.
Rules our writing follows
- We describe results by what was measured and how.
- We do not advertise instrument makers, models or other companies' platforms.
- We describe our services in a way that leaves room for new methods.
- Example charts are marked as examples. Real results are always tied to a specific sample, method and set of conditions.
Published definitions behind these terms
- Binding and potency terms (Kd, EC50, IC50, potency, efficacy): Neubig RR et al. International Union of Pharmacology terms and symbols in quantitative pharmacology. Pharmacol Rev 2003; 55(4):597–606. PMID 14657418. PubMed record
- Detection and measuring limits: Armbruster DA, Pry T. Limit of blank, limit of detection and limit of quantitation. Clin Biochem Rev 2008; 29 Suppl 1:S49–S52. PMID 18852857. PubMed record
- Gene expression by qPCR: Bustin SA et al. The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments. Clin Chem 2009; 55(4):611–622. PMID 19246619. PubMed record
- Method validation terms: ICH Q2(R2) Validation of Analytical Procedures, International Council for Harmonisation, 2023. Guideline (PDF)
